When to Use cryogenic pipe clamps?

Author: Geym

Aug. 06, 2024

59 0 0

Tags: Construction & Real Estate

Cryogenic Pipe Insulation Supports – Cold Shoes - Products

Download Pre-Insulated Pipe Supports General Information

View Details

 

Scope
This specification covers the requirements for the design, fabrication, and use of our pre-insulated low-temperature pipe supports. These supports are for pipes having surface temperature ranges of &#;460 ˚F (-273 ˚C ) to 280 ˚F (138 ˚C ).

General Requirements
&#; Cryogenic pipe supports shall comply with the following standards:
A. ANSI/ASME B31.1 & B31.3
B. Manufacturers Standardization Society SP-58, 69, & 89.
&#; The following criteria shall be considered in the selection of low-temperature pre-insulated pipe supports:
A. Vertical, lateral and axial support design load limits.
B. Vertical, lateral, and axial support design travel limits.
C. The temperature of the cryogenic pipe support, at the pipe surface, and ambient conditions.
D. All test or pre-operational loads that may exceed normal operating conditions.
E. Any dimensional clearances needed during installation and operation should be specified.
F. Material for any items that will be welded directly to the pipe.
G. All loading and displacements caused by seismic, hydraulic surge, or other disturbances.
H. The temperature at the support steel.
&#; Upon request by the purchaser or the end user, design calculations of supports will be made available for review.
&#; Upon request by the purchaser or the end user, localized stress calculations for lugs and other welded attachments will be made available for review.
&#; Prior to placing an order, all special requirements such as mill test reports, material certification or non-standard materials must be specified.

Design Criteria
&#; The load bearing insulating materials used in the pre-insulated pipe support shall be the same material that was used to rate the support.
&#; At the request of the end user or the purchaser, we will make available compressive strength and thermal conductivity testing results of the high-density polyurethane in the format provided by MSS SP-89. Testing will be done at the maximum temperature of -196oC .
&#; A description of the quantity of load that can be applied to the support shall be provided for evaluation upon request. A minimum safety factor of 5 at the system design temperature shall be used to determine the maximum load.
&#; Testing for compressive strength properties shall comply with ASTM D, the standard testing method, for compressive properties of Rigid Cellular Plastics.
&#; Testing for thermal conductivity shall comply with ASTM C177, Steady-State Heat Flux Measurements, and Thermal Transmission Properties, by means of the Guarded Hot Plate Apparatus.
&#; Load bearing element capacity shall be demonstrated at the system design temperature and load.
&#; The pre-insulated pipe support assembly shall exert enough clamping force to assure that the support will move axially with the pipe and will not slip when under design conditions.
&#; All slide plate surfaces shall be designed so that the coefficient of friction will be limited to .1 for the design life without requiring lubrication. Any friction reducing material that requires bonding shall be bonded to a backing structure prior to shipment.
&#; High-density polyurethane shall have the following maximum thermal conductivity:
A. 10 lb./cu.in. foam &#; .114 BTU-in/hr-ft2 &#; oF (. W/m- o K)
B. 14 lb./cu.in. foam &#; .12 BTU-in/hr-ft2 &#; oF (. W/m- o K)
C. 20 lb./cu.in. foam &#; .22 BTU-in/hr-ft2 &#; oF (. W/m- o K)
&#; CFC&#;s shall not be used in the manufacture of high-density polyurethane foam.

Link to zhiang

Fabrication
&#; All polyurethane foam shall be monolithic and molded oversized so that excess material shall be removed by cutting to achieve the final finished dimensions, the outer skin shall be removed.
&#; The pre-insulated pipe support shall:
A. Come pre-assembled with sufficient insulation extending past the outer metal jacket, allowing the pipe insulator to butt the line insulation against it.
B. All exposed surfaces will be coated with mastic to protect the foam from moisture and UV degradation. The mastic will have a minimum perm rating of .02 (ASTM E-96).
C. The vapor barrier between the metallic jacket and the insulating material will also have a perm rating of .02.
D. The ID and OD dimensions of the insulation shall conform to ASTM specification C585 unless otherwise specified.
&#; Designs having sliding surfaces shall incorporate two slide plates at each surface. Each slide plate will be made of 3/32&#; thick glass filled reinforced PTFE, 25% glass filled, bonded to a 10GA carbon steel backing plate. The PTFE, 25% glass filled, will be recessed ¼&#; from the edge of the plate.
&#; All welding shall comply with B31.3 and B31.1 Piping Code and AWS D1.1
&#; The following items unless otherwise noted on contract drawings shall be in accordance with the following:
A. Structure shapes and plate: ASTM A-36
B. Bolts and studs: ASTM A-307
C. Nuts: A563

The Complete Guide to Cryogenic Pipe Supports

In order to assign cryogenic pipe supports to a piping system one must first identify why the pipe needs to insulated in the first place. Next is to identify the environmental conditions in which the pipe exists. Thirdly, selection of appropriate insulation and exterior materials. And lastly perform a heat gain calculation.

In the first step, the planner needs to identify why the LNG pipe is in need of being insulated. The two most common reasons for insulating LNG pipes are to minimize condensation on the outer surface of the insulation system, limit heat input to the LNG within, and control the processes that cause sublimation of the liquid within the piping. A common rule of thumb in the cryogenic pipe support industry is to limit the heat gain by the insulation system to the outer shell area of &#;&#;&#;8 Btu / hrft2 (25 W / m2). There are other possible purposes but most of them are achieved by addressing these two.

[See also Factors Influencing the Likelihood of Surface Condensation on Mechanical Systems Insulation, Jim Young, Insulation Outlook, July and August, . for more information.]

Contact us to discuss your requirements of cryogenic pipe clamps. Our experienced sales team can help you identify the options that best suit your needs.